ISO 9001 / NSF-61 VERIFIEDSeries-9 Architecture

Advanced Fluid Engineering & Sub-Micron Filtration

SYNPORE engineers precision membrane media and skid-mounted filtration architectures for critical infrastructure. Designed for industrial manufacturing plants and municipal water facilities demanding stringent regulatory compliance and uncompromising barrier integrity.

POROSITY
0.02 µm
Absolute Rating
Sub-Micron Matrix
FLOW-VEL
99.98%
Pathogen Barrier
ISO 13485 / NSF-61
PRESSURE
140 PSI
Delta Tolerance
Continuous Duty
Zero-bypass hydraulic seal integrity
Continuous 100% steam sterilizable
Industrial membrane filter cross section schematic showing porous polymer matrix
SYN-316L Core
Sanitary Flange

Patented multi-layer sinter structure offering uniform delta pressure.

Standard Product Classifications

Engineered Filtration Categories

Industrial fluid and gas separation systems manufactured to exacting tolerances for municipal facilities and critical manufacturing plants.

Division: Architecture 01
0.02 MICRONUF-SPEC 440
Municipal Water Treatment
Engineered hollow-fiber and ceramic membrane skids delivering high-volume pathogen separation and continuous regulatory compliance.
CALIBRATIONContinuous flux capacity up to 12.5 MGD
99.99% EFFICIENCYISO-16890 / HEPA
Factory Air Purification
Heavy-duty catalytic and sintered particulate systems capturing industrial aerosols, volatile emissions, and microscopic airborne dust.
CALIBRATIONHigh thermal tolerance up to 450 C
316L POROUSCATALOG ID 88
Replacement Filter Media
Precision-machined stainless steel porous metal tubes, replacement cartridges, and membrane elements calibrated for standard housings.
CALIBRATIONDirect drop-in fits for ASME vessels
Core Architecture // Proprietary Media

Engineered Membrane Performance

Synpore porous media are precision-formed for severe municipal and industrial fluid separation where polymer alternatives degrade.

SPEC-01 // DURABILITY

Sintered Porous Alloy Matrix

Engineered 316L stainless steel and titanium structures withstand continuous differential pressures exceeding 25 bar without media migration or pore collapse.

Operating Limit25+ Bar Delta-P
SPEC-02 // HYDRAULICS

Low Differential Flux Resistance

Precision pore geometry reduces parasitic pump workloads by up to 28%, sustaining high permeate flow velocities under standard hydraulic head pressures.

Energy Reduction-28% kWh/m3
SPEC-03 // SERVICE LIFE

In-Situ Backpulse Regeneration

Automated reverse fluid and sonic pulse cleaning restore flux rates without system disassembly or repeated caustic chemical bathing routines.

Operational Life10+ Years MTBF
SPEC-04 // COMPLIANCE

Validated Industrial Certifications

Full material traceability meeting ASME Section VIII pressure vessel codes, NSF/ANSI 61 drinking water protocols, and ISO 9001 manufacturing rigor.

CertificationsNSF 61 / ASME VIII
Quality AssuranceEvery production lot undergoes bubble-point testing and helium leak detection down to 0.1 micron.
View Liquid Filtration

Regulatory Assurance & Validation

Industry Certifications & Global Standards

Every Synpore membrane system and pressure vessel is engineered, manufactured, and independently tested to comply with international municipal, biopharma, and industrial codes.

ISO 9001:2015

International Organization for Standardization

2027

Quality Management Systems

Design, fabrication, and validation of precision membrane filtration units.

Active / Audited 2024
QMS-CERT-9001

NSF/ANSI 61

NSF International

2026

Drinking Water System Components

Health effects compliance for municipal water and direct fluid contact media.

Full Compliance
TOXIC-TEST-061

ASME BPE

American Society of Mechanical Engineers

2026

Bioprocessing Equipment Standard

Sanitary stainless vessels, electropolished surfaces, and weld integrity.

Section VIII Div 1
ASME-STAMP-U

FDA 21 CFR 177

U.S. Food and Drug Administration

Active

Polymer Membrane Compliance

Sub-micron synthetic membranes qualified for pharmaceutical & food liquid streams.

Class VI Passed
CFR-177-2600

CE / PED 2014/68/EU

European Conformity

2028

Pressure Equipment Directive

Sound engineering practice and pressurized filter skid safety conformity.

Module H Certified
EU-PED-CE1020

EPA Safe Drinking Water

U.S. Environmental Protection Agency

Perpetual

SDWA Pathogen Barrier Criteria

Surpasses 4-log Giardia and Cryptosporidium removal performance thresholds.

LT2 Rule Compliant
EPA-LT2-VALID

Traceability Protocol: Full Mill Certification & Material Test Reports (MTRs) Provided Per Unit

Need compliance files for audit review? Request Documentation Package

Procurement Technical Guidelines

Frequently Answered Procurement Questions

Review verified answers on engineering parameters, system customization, warranty frameworks, and commercial delivery protocols for Synpore filtration infrastructure.

0.1 – 100 MICRONPore Retention Range
ASME SEC VIIIVessel Fabrication Standard
24 MONTHSIndustrial Warranty Term

Custom Engineering Review

Direct access to specialized process technicians

Have specific operating flow curves, slurry parameters, or customized manifold requirements? Our applications engineering division supplies turnkey sizing schematics within 24 hours.

Mon-Fri: 8am – 6pmcontact@synpore.com

Flow sizing is determined by fluid viscosity, operating temperature, continuous volumetric demand, and maximum allowable clean differential pressure (Delta-P under 2.5 PSI). Synpore applications engineers model these variables against our sub-micron membrane matrices to establish minimum surface area, preventing premature particulate loading.

Category: Flow Sizing & SUT|Documentation Attached

Need a full technical submittal package with CAD dimensional diagrams and MTRs?

Email Engineering Desk